Fire Rated Frames

ACS’s fire-rated aluminum frame options integrate seamlessly into modern commercial interiors, providing up to 90 minutes of fire resistance without compromising on style or functionality. Featuring concealed intumescent technology and wide stops for easy hardware installation, our fire-rated solutions deliver the perfect balance of protection and aesthetics for offices, healthcare facilities, hospitality spaces, and more.

FEATURES

  • UBC 7-2 Positive Pressure Rated

  • 20min & 90min Rated

  • Sidelight Available for 20min Rating

  • Concealed Intumescent In Frame

1
2
3
Image 13

20 Min Rated

Positive Pressure

Series

Frame Stop Profile

Sizes & Requirements

Single

*Max 4ft x 9ft

Single w/ Sidelight

Max 6ft x 9ft

(*4ft Wide Max Door + 2ft Wide Max Sidelight)

Glass supplied by others.

Pair

**Max 8ft x 9ft

*Doors over 3′-6″ wide require an additional surface mounted intumescent strip applied to the top of the door. This additional intumescent is NOT provided by ACS. 

**All pairs of doors require an additional surface mounted intumescent strip applied to the top of the door, and either a surface mounted or machined into the stile of one of the doors. This additional intumescent is NOT provided by ACS. 

Additional Notes:

  • Doors must be approved and listed as fire doors by the manufacturer and comply with the minimum 20 minute construction and bare a “20 minute positive pressure” label.
  • Door hardware must be certified and approved by the manufacturer for fire rated doors in each application.
  • No transoms or borrowed lites

90 Min Rated

Positive Pressure

Series

Frame Stop Profile

Sizes & Requirements

Single

Max 3ft x 9ft

Max 4ft x 8ft

Pair

Max 6ft x 8ft

  • ACS 90 minute frames qualifies for use in positive pressure assemblies with Category “A” doors, or with Category “B” doors utilizing Category “G” edge sealing systems.
  • Maximum frame size is 6′-0″ x 8′-0″ utilizing a minimum 4-7/8″ wall thickness frame.
  • Doors must be approved and listed fire doors as certified by the manufacturer and must comply with minimum 90-minute construction using one of the methods outlined herein.
  • Doors must bear a 90-minute “positive pressure” label.
  • Varying door cutouts and applications are dependent upon the door manufacturer’s fire labeling certification.
  • Hardware must be approved and listed as fire-rated by the manufacturer for each application. Varying hardware applications are dependent upon the hardware manufacturer’s fire labeling certification.